Equipment / configured to order
Linear Pouch Automatic Electrolyte Injection Equipment
The SZ-AZY200H is designed for the automatic vacuum electrolyte injection and sealing process of pouch cells. It features code scanning and weighing before electrolyte injection, automatic vacuum electrolyte injection, vacuum dwelling, automatic sealing code scanning and weighing after injection, unloading mechanism, automatic NG rejection, and a data management system for cell weight and moisture information.

Typical applications
Discuss your intended cell design and application with our team.
Customization scope
Equipment configuration, dimensions and process parameters can be customized to customer requirements.
Installation, commissioning, process handover and operator training available.
Global after-sales support with spare parts supply.
--
*Pictures for Reference Only** — All product pictures in this document are for reference only. The actual delivered product may differ in appearance and configuration, as each unit is built to the customer's specifications. Please refer to the order confirmation for the final configuration.
Model: SZ-AZY200H Category: Cell Finishing → Electrolyte Injection
Note: Product pictures are for reference only. The actual delivered machine may differ in appearance and configuration, as each unit is built to the customer's specifications.
Key Features
- High precision: ±1% electrolyte injection accuracy; vacuum degree 5 – 40 kPa
- Intelligent dwelling: Stepped type of vacuum dwelling (1–30 to 35–85 kPa), adjustable time 1–320 s
- Vacuum pre-sealing: Sealing head temperature 25–250 °C (± 3 °C), sealed sealing head design to prevent leakage
- Applicable cell dimensions: Height 150–300 mm (total height ≤ 320 mm), Thickness ≤ 15 mm
Process Flow
Cell away by manual → Code Scanning & Weighting (Before Injecting Electrolyte) → Cell Into Fixture → Vacuum Injection → Vacuum Dwelling Stage 1 → Vacuum Dwelling Stage 2 → Vacuum Degassing → Cell Away From Fixture → Code Scanning & Weighting After Injection → Cell Into Fixture → Bottom Box Cooling & Output
Technical specifications
| Injection Accuracy | ± 1% |
|---|---|
| Vacuum Degree | 5 – 40 kPa |
| Vacuum Dwelling | Stepped 1–30 to 35–85 kPa, time 1–320 s (adjustable) |
| Sealing Head Temperature | 25–250 °C (± 3 °C) |
| Applicable Cell Dimensions | Height 150–300 mm (total height ≤ 320 mm); Thickness ≤ 15 mm |
| Functions | Code scanning & weighing before injection, automatic vacuum injection, vacuum dwelling, automatic sealing, scanning & weighing after injection, automatic NG rejection, data management |
Information for project review
Please share your cell format, chemistry, target capacity, process scope, facility conditions and voltage standard.
Training in China
Training at our China facility is available for this product. Scope, schedule and language are agreed for each project.